Wuhan Wugao Electric Measurement Co., Ltd

WDHGQ Integrated Current and Voltage Transformer Field Calibration Instrument

WDHGQ integrated current and voltage transformer field calibrator, integrated current and voltage transformer error field tester adopts the measurement principle of small signal method, a single instrument can complete the current and voltage transformer error test, which greatly facilitates the field measurement device On-site inspection work. The Complete machine weight is less than 6.0Kg, complete machine volume: 472mm 355mm 168mm small volume, light weight, really easy to carry.


Products Inquiry

Product Details

1651220628107467.jpg

(1) CT variable ratio range:

The 5A / 5A~25000A / 5A (5A / 1A / 1A~5000A / 1 A) turn ratio error of ± 0.2%

Error measurement range:

5A/5A5000A/5A5A/1A5000A/1A

Accuracy range of the inspected current transformer: 1.0, 0.5, 0.5S, 0.2, and 0.2S

For 1% (grade S) or 5% test points, the test error mainly lies in the deviation of the instrument automatic picking point, that is, the deviation of the percentage table reading and the heart piercing location of 1 turn (which also exists in the traditional verification methods).Therefore, the error difference between the two verification methods may be large or small.

Machine accuracy: 1 / 3 of the measured current transformer error limit (see Appendix I) (Note: the standard transformer and calibration errors are 1 / 5 and 1 / 10 of the transformer error limit and Z are 1 / 10, the electromagnetic field is 1 / 10 of the transformer error limit, and the other errors are 1 / 10 of the transformer error limit. The comprehensive error is added to the above, as 1 / 3.33 <1 / 3 of the error limit of the inspected transformer. )

accuracy:  ±0.05%

(2) PT ratio range: full range measurement (electromagnetic type) ±0.2%

Error measurement range:

Primary voltage: 3-35KV/√3 (non-standard primary voltage is also available)

Secondary voltage: 100V, 100v/√3

6kV/100V 10kV/100v 20kV/100V 35kV/100V

6kV/√3/100V/√3 10kV/√3/100v/√3 20kV/√3/100V/√3

35kV/√3/100V/√3 66kV/√3/100V/√3 110kV/√3/100v/√3

power factor:  0.0-1.0

accuracy:  ±0.05%

direct-current resistance:  0.0-0.1Ω ±3%

0.1-50Ω       ±1%

CT secondary load:  1Ω-25Ω ±2%

PT secondary load:  1VA-500VA ±2%

Verification: Voltage range: 0-100V (meter error 0.5%)

Difference: 0.001% -3% (100V)

Angle difference: 0.00 '-50' (100V)

D±Error: X= (2% X + 2% Y, 2 words)±

D±Y= (2% X + 2% Y, 2 words)±

Guide guide: 0.1mS-99.9mS

D±Error: X= (2% X + 2% Y, 2 words)±

D±Y= (2% X + 2% Y, 2 words)±

 

working power supply:  AC 220V 10%/50Hz 2%±±

ambient temperature:  0-40℃

Complete machine power consumption:  30W (Static) 150W (Work)

ambient temperature:  0-40℃

ambient humidity:  25 <85% at ℃

Operating Weight:  6.0Kg,

Complete machine dimension:  472mm*355mm*168mm