WDYDJ series withstand voltage test device is a strict, effective and direct method to identify the dielectric strength of power equipment. It can check out those concentrated defects that are more dangerous, and has a decisive role in judging whether the power equipment can continue to participate in the operation. It is an important means to ensure the insulation level of the equipment and avoid the occurrence of insulation accidents.
This device is a high-performance withstand voltage test equipment designed according to the national power industry standard. It is used to conduct dielectric strength tests under specified voltages for various electrical products, electrical components, insulating materials, etc. Find the insulation defects of the test object and measure the ability of overvoltage.
1. Pressure control box (unit) parameters: (see the table below for general parameters) | |||||||
Model Specifications | capacity | Power supply | Output | Weight(kg) | |||
Phase | (V) | (A) | (V) | (A) | |||
WDYD—2/220 | 2 | 1 | 220 | 10 | 0-250 | 8 | 14 |
WDYD—3/220 | 3 | 1 | 220 | 15 | 0-250 | 12 | 16 |
WDYD—5/220 | 5 | 1 | 220 | 25 | 0-250 | 20 | 18 |
WDYD—10/220 | 10 | 1 | 220 | 50 | 0-250 | 40 | 80 |
WDYD—15/400 | 15 | 2 | 380 | 37.5 | 0-430 | 34.8 | 90 |
WDYD—20/400 | 20 | 2 | 380 | 50 | 0-430 | 46.5 | 100 |
WDYD—25/400 | 25 | 2 | 380 | 62.5 | 0-430 | 58.1 | 120 |
WDYD—30/400 | 30 | 2 | 380 | 75 | 0-430 | 69.7 | 140 |
WDYD—50/400 | 50 | 2 | 0.38 | 125 | 0-430 | 116.2 | 160 |
WDYD—100/400 | 100 | 2 | 380 | 250 | 0-430 | 232.5 | 50 |
2. High voltage test transformer parameters:
Size | capacitance ( kVA) | low voltage side | High voltage side | Measuring ratio | 60 minutes temperature rise (℃) | Impedance voltage% | No-load current % | weight | Dimension | ||
Voltage | Current | Voltage | Current | ||||||||
V | A | V | mA | kg | mm×mm×mm | ||||||
1.5/50 | 1.5 | 200 | 7.5 | 50 | 30 | 500 | 50 | 10 | <4 | 19.5 | 200×275×640 |
3/50 | 3 | 200 | 15 | 50 | 60 | 500 | 50 | 10 | <4 | 27 | 240×300×690 |
5/50 | 5 | 200 | 25 | 50 | 100 | 500 | 50 | 10 | <4 | 52 | 250×355×710 |
10/50 | 10 | 200 | 50 | 50 | 200 | 500 | 50 | 10 | <4 | 80 | 260×375×750 |
15/50 | 15 | 400 | 37.5 | 50 | 300 | 500 | 50 | 8 | <4 | 120 | 270×420×800 |
20/50 | 20 | 400 | 50 | 50 | 400 | 500 | 50 | 8 | <4 | 140 | 285×440×820 |
30/50 | 30 | 400 | 75 | 50 | 600 | 500 | 50 | 8 | <4 | 155 | 295×386×840 |
50/50 | 50 | 400 | 125 | 50 | 1000 | 500 | 50 | 8 | <4 | 184 | 320×416×910 |
10/100 | 10 | 400 | 50 | 100 | 100 | 1000 | 50 | 10 | <4 | 135 | 350×475×1300 |
15/100 | 15 | 400 | 37.5 | 100 | 150 | 1000 | 50 | 8 | <4 | 150 | 510×390×1320 |
20/100 | 20 | 400 | 50 | 100 | 200 | 1000 | 50 | 8 | <4 | 215 | 540×400×1340 |
30/100 | 30 | 400 | 75 | 100 | 300 | 1000 | 50 | 8 | <4 | 250 | 560×410×1360 |
50/100 | 50 | 400 | 125 | 100 | 500 | 1000 | 50 | 8 | <4 | 290 | 600×460×1410 |
10/150 | 10 | 200 | 50 | 100 | 66.7 | 1500 | 50 | 10 | <4 | 180 | 265×380×1750 |
15/150 | 15 | 400 | 37.5 | 150 | 100 | 1500 | 50 | 8 | <4 | 200 | 510×390×1800 |
20/150 | 30 | 400 | 50 | 150 | 133.3 | 1500 | 50 | 8 | <4 | 220 | 540×415×1800 |
30/150 | 30 | 400 | 75 | 150 | 200 | 1500 | 50 | 8 | <4 | 280 | 560×430×1800 |
50/150 | 50 | 400 | 125 | 150 | 333.3 | 1500 | 50 | 8 | <4 | 340 | 640×490×1850 |
Note: The parameters of the AC-DC dual-purpose test transformer are the same as the above table, the rated DC voltage in the DC parameters is 1.4 times that of the AC, and the rated DC current is 0.7 times the AC current. According to the user's needs, a medium-voltage tap of 5-15kV can be extracted from the high-voltage winding for the AC withstand voltage test of the high-voltage motor. Test transformers with special specifications can also be customized.