WDCT-103 Automatic Current Transformer Field Calibration Instrument

WDCT-103 current transformer field tester is developed with high-end testing technology, large-scale electronic line design and in accordance with relevant national regulations.It solves the problems of large working intensity and tedious operation of current transformer, voltage transformer and on field verification. At the same time, the product is reliable and powerful


Products Inquiry

Product Details

1651220628107467.jpg

1. Current transformer error measurement section

1) Machine accuracy: 1 / 3 of the error limit of the measured current transformer

2) Test range: 5A / 5A~25000A / 5A or 5A / 1A~6300A /


Secondary current of 5A transformer rated primary current range

5

7.5

10

15

20

25

30

40

50

60

75

80

100

120

150

160

200

250

300

315

400

500

600

630

750

800

1000

1200

1250

1500

1600

2000

2500

3000

3150

3200

4000

5000

6000

6300


A secondary current of 1A transformer rated primary current range

5

7.5

10

15

20

25

30

40

50

60

75

80

100

120

150

160

200

250

300

315

400

500

600

630

750

800

1000

1200

1250

1500

1600

2000

2500

3000

3150

3200

4000

5000

6000

6300


Note: The current transformer with a secondary current of 1A can be comparable to 31,500 A / 1A by equal-safety turn measurement.

Other test methods for the current transformer change ratio appearing at the end in the table are as follows:

Test the current transformer using the isometric turn method, e. g., to test the 1000A / 5A transformer, please put the test line of the instrument through the measured current transformer into two turns, and then the current transformer test interface in the instrument is 500A.This test method does not affect the validity of the transformer test data.

Similarly, other variable ratios use the following processing methods:

Rated once (A)

Wear the number of turns

Instrument primary current (A)

80

2

40

120

2

60

8000

2

4000

12000

2

6000

3) Operating range of the measured current transformer: 1%~200%

4) Secondary load: 2.5VA~300VA, COS =0.1~1.0

5) Accuracy range of the inspected current transformer: 1.0, 0.5, 0.5S, 0.2, and 0.2S

6) Resistance and conductor measurement error is 5.0%

7) measuring range:  R: 0.00Ω~20.0Ω Y: 0.000mS~100.0Ms


2. Voltage transformer tester part

1) cophase component:

DX= ± (X 2% + Y 2% ±, 2 words)

DY= ± (X 2% + Y 2% ± in 5 words)

Display values of the "X", "Y" —— instruments

Quantization error of the "5-word" —— instrument

2) Ptable: Level 1

3) measuring range:

F : 0.0000%200.0%

δ 0.000′999.9′


3. Power consumption of the instrument: 20VA