Wuhan Wugao Electric Measurement Co., Ltd

WDXZ Frequency conversion series resonance withstand voltage test device

Application of WDXZ frequency conversion series resonance withstand voltage test device

1. AC withstand voltage test of 6kV-500kV high-voltage cross-linked cables

2. AC withstand voltage test of various generators

3. AC withstand voltage test of 10-500kV switchgear, GIS and SF6 switches

4. Power frequency withstand voltage test of 6kV-500kV transformers

5. AC withstand voltage test of other power high-voltage equipment such as busbars, bushings, and transformers.

6. The complete set of equipment consists of variable frequency power supply, excitation transformer, reactor and voltage divider.

Products Inquiry

Product Details

1651905461626190.jpg

Technical parameters of WDXZ-108kVA/108kV series resonance withstand voltage test device

(1) WDXZ refers to the manufacturer code

 108 refers to the maximum rated capacity that the device can output, in kVA

 108 refers to the voltage level that the device can output, in kV;


(2) Technical indicators of WDXZ-108kVA/108kV series resonance withstand voltage test device

1. Rated voltage:

27kV---meet the AC withstand voltage test of 10kV cable;

54kV---meet 10kV system, 35kV cable AC withstand voltage test;

108kV---meet the AC withstand voltage test of 35kV system;

2. Output voltage waveform distortion rate: <1.0%

3. Allowable continuous working time: one-time work for 15 minutes under rated conditions,

4. The quality factor of the device itself: Q>50

5. Quality factor under full load during thermal generator test: Q>10 (related to load)

6. Quality factor under full load during cable test: Q>30 (related to load)

7. Quality factor at full load of main transformer test: Q>30 (related to load)

8. Quality factor of GIS, switch and other tests at full load: Q>50 (related to the load)

9. Input power: single-phase 380V

10. Frequency adjustment range: 20Hz~300Hz

11. System measurement accuracy: 1.5%

12. The device has protection functions such as overvoltage, overcurrent, and zero start


A. Generator AC withstand voltage selection guide

ItemConsole (kVA/V)Excitation TransformerHigh Voltage ReactorCapacitive Voltage DividerApplicable test product
WDXZ-100/2510kVA/380V  1 unit10kVA--2.5kV/3.5kV/0.4kV     1pc100kVA/25kV    Adjustable 1 section30kV/3000pF  1pcSingle-phase to ground capacity 0.2~0.5uF, 10.5kV generator
WDXZ-200/2520/380 1 unit20--2.5/3.5/0.4         1pc200/25               Adjustable 1 section30/3000      1pcSingle-phase to ground capacity 0.4~1.0uF, 10.5kV generator
WDXZ-300/2530/380 1 unit30--2.5/3.5/0.4           1pc300/25              Adjustable 1 section30/3000      1pcSingle-phase to ground capacity 0.6~1.5uF, 10.5kV generator
WDXZ-400/2540/380 1 unit40--2.5/3.5/0.4           1pc400/25               Adjustable 1 section30/3000      1pcSingle-phase to ground capacity 0.8~2.0uF, 10.5kV generator
WDXZ-200/5020/380 1 unit20--5/7/0.4                 1pc200/50               Adjustable 1 section50/2000      1pcSingle-phase-to-ground capacitance 0.1~0.25uF, generator below 20kV
WDXZ-300/5030/380 1 unit30--5/7/0.4                1pc300/50                Adjustable 1 section50/2000      1pcSingle-phase-to-ground capacitance 0.16~0.4uF, generator below 20kV
WDXZ-400/5040/380 1 unit40--5/7/0.4                 1pc

300/50              Adjustable 1 section    100/50                Fixed 1 section

50/2000      1pcSingle-phase-to-ground capacitance 0.16~0.5uF, generator below 20kV
WDXZ-500/5050/380 1 unit50--5/7/0.4                 1pc

300/50              Adjustable 1 section

200/50               Fixed 1 section

50/2000      1pcSingle-phase-to-ground capacity 0.16~0.75uF, generator below 20kV
WDXZ-600/5060/380 1 unit60--5/7/0.4                 1pc400/50               Adjustable 1 section200/50               Fixed 1 section    
50/2000      1pcSingle-phase-to-ground capacity 0.2~0.9uF, generator below 20kV
WDXZ-700/5070/380 1 unit70--5/7/0.4                 1pc

500/50             Adjustable 1 section

200/50            Fixed 1 section  

50/2000      1pcSingle-phase-to-ground capacity 0.25~1.0uF, generator below 20kV
WDXZ-800/5080/380 1 unit80--5/7/0.4                 1pc600/50              Adjustable 1 section 200/50             Fixed 1 section  
50/2000      1pcSingle-phase-to-ground capacity 0.3~1.1uF, generator below 20kV
WDXZ-900/5090/380 1 unit90--5/7/0.4                  1pc700/50                Adjustable 1 section200/50               Fixed 1 section    
50/2000      1pcSingle-phase-to-ground capacity 0.4~1.3uF, generator below 20kV
WDXZ-1000/50100/380 1 unit100--5/7/0.4               1pc700/50               Adjustable 1 section300/50                Fixed 1 section    
50/2000      1pcSingle-phase-to-ground capacity 0.4~1.4uF, generator below 20kV
WDXZ-1200/50120/380 1 unit120--5/7/0.4                1pc800/50                Adjustable 1 section400/50               Fixed 1 section   
50/2000      1pcSingle-phase-to-ground capacity 0.5~1.7uF, generator below 20kV
WDXZ-1500/50150/380 1 unit150--5/7/0.4                1pc1000/50              Adjustable 1 section500/50                 Fixed 1 section  
50/2000      1pcSingle-phase-to-ground capacity 0.5~2.0uF, generator below 20kV
WDXZ-1800/50180/380 1 unit180--5/7/0.4                1pc

1200/50              Adjustable 1 section

300/50                Fixed 1 section 

50/2000      1pcSingle-phase-to-ground capacity 0.8~2.5uF, generator below 20kV
WDXZ-2000/50200/380 1 unit200--5/7/0.4                1pc

1200/50            Adjustable 1 section

400/50              Fixed 2 sections   

50/2000      1pcSingle-phase-to-ground capacity 0.8~2.8uF, generator below 20kV
WDXZ-2500/50250/380 1 unit250--5/7/0.4                1pc

1500/50           Adjustable 1 section

500/50            Fixed 2 sections   

50/2000      1pcSingle-phase-to-ground capacity 0.8~3.5uF, generator below 20kV
WDXZ-2750/50280/380 1 unit280--5/7/0.4                1pc

1750/50           Adjustable 1 section

500/50             Fixed 2 sections  

50/2000      1pcSingle-phase-to-ground capacity 1.2~4.0uF, generator below 20kV


B. Selection guide for AC withstand voltage of substations

ItemAC POWER SOURCEexciting transformerHigh Voltage Resonant ReactorCapacitive Voltage DividerApplicable test product
WDXZ-50/503--220/380     1pc3--1.2/2.4/0.2/0.4          1pc22/22              Section 230/3000         1pc

8.7/10kV, 1km of cables below 300mm2;

Substation electrical equipment below 10kV

WDXZ-108/1086--220/380    1pc6--1.2/2.5/5/0.2/0.4        1pc27/27              Section 4110/1000         1pc

8.7/10kV, 1km of cables below 300mm2;

Substation electrical equipment below 10kV

WDXZ-200/20010--220/380    1pc10--1.2/2.5/5/10/0.2/0.4     1pc50/50              Section 4200/500          1pc

8.7/10kV, 2km of cables below 300mm2;

26/35kV, 1km of cables below 300mm2;

64/110kV, 0.1km of cable below 300mm2;

Substation electrical equipment below 110kV

WDXZ-270/27015--220/380    1pc15--1.2/2.5/5/15/0.2/0.4     1pc45/45             Section 6270/500      1pc

8.7/10kV, cable below 300mm2 3km; 26/35kV, cable below 300mm2 1km;

64/110kV, 0.2km of cables below 300mm2; electrical equipment of substations below 110kV

WDXZ-400/40020--220/380   1pc20--1.2/2.5/5/20/0.2/0.4    1pc50/50              Section 8400/300      1pc

8.7/10kV, 4km of cables below 300mm2;

26/35kV, 2km of cables below 300mm2;

64/110kV, 0.3km of cables below 300mm2;

Substation electrical equipment below 220kV

WDXZ-800/40030--220/380   1pc30--1.2/2.5/5/20/0.2/0.4   1pc100/50            Section 8400/300       1pc

8.7/10kV, cable below 300mm2 8km; 26/35kV, cable below 300mm2 4km;

64/110kV, 0.6km cable below 300mm2;

Substation electrical equipment below 220kV

WDXZ-500/50025--220/380  1pc25--1.2/2.5/5/25/0.2/0.4    1pc50/50             Section 10500/200        1pc

8.7/10kV, cable below 300mm2 5km; 26/35kV, cable below 300mm2 2km;

64/110kV, 0.4km of cables below 300mm2;

Substation electrical equipment below 220kV

WDXZ-1600/80040--220/380   1pc40--2.5/5/20/40/0.2/0.4    1pc400/200           Section 4800/200       1pc

64/110kV, 2km of cables below 300mm2;

127/220kV, 0.5km of cable below 630mm2;

Substation electrical equipment below 550kV


C. Selection guide for cable AC withstand voltage test

ItemAC POWER SOURCEexciting transformerHigh Voltage Resonant ReactorCapacitive Voltage DividerApplicable test product
WDXZ-44/443kVA/220V/380V    1pc3kVA/1.2kV/2.4kV/0.2kV/0.4kV    1pc22kVA/22kV     Section 230kV/3000pF    1pc 8.7/10kV, 1km of cables below 300mm2;
Substation electrical equipment below 10kV
WDXZ-88/445kVA/220V/380V     1pc5kVA/1.2kV/2.4kV/0.2kV/0.4kV    1pc44kVA/22kV     Section 250kV/3000pF    1pc8.7/10kV, 2km of cables below 300mm2;
Substation electrical equipment below 10kV
WDXZ-132/666kVA/220V/380V      1pc6kVA/1.2kV/2.4kV/0.2kV/0.4kV   1pc44kVA/22kV    Section 370kV/1500pF  1pc8.7/10kV, 3km of cables below 300mm2;
26/35kV, 1km of cables below 300mm2;
Substation electrical equipment below 10kV
WDXZ-176/6610kVA/220V/380V      1pc10kVA/1.2kV/2.4kV/0.2kV/0.4kV  1pc44kVA/22kV     Section 470kV/1500pF  1pc8.7/10kV, 4km of cables below 300mm2;
26/35kV, 1km of cables below 300mm2;
Substation electrical equipment below 10kV
WDXZ-220/6612kVA/220V/380V     1pc12kVA/1.2kV/2.4kV/0.2kV/0.4kV   1pc55kVA/22kV      Section 470kV/1500pF  1pc8.7/10kV, 5km below 300mm2;
 26/35kV, 1km of cables below 300mm2;
Substation electrical equipment below 10kV
WDXZ-264/6615--220/380          1pc15--1.2/2.4/0.2/0.4         1pc44/22               Section 670/1500    1pc8.7/10kV, 6km below 300mm2;
26/35kV, cable below 300mm2 2km; 10kV substation electrical AC withstand voltage test
WDXZ-135/1087.5--220/380        1pc7.5--1.2/2.5/5/0.2/0.4        1pc33.75/27             Section 4110/1000   1pc8.7/10kV, 3km of cables below 300mm2;
26/35kV, 1km of cables below 300mm2;
Substation electrical equipment below 35kV
WDXZ-270/10815--220/380         1pc15--1.2/2.5/5/0.2/0.4        1pc67.5/27                 Section 4110/1000   1pc8.7/10kV, 6km cable below 300mm2;
26/35kV, 2km of cables below 300mm2;
Substation electrical equipment below 35kV
WDXZ-405/10825--220/380          1pc25--1.2/2.5/5/0.2/0.4        1pc67.5/27               Section 6110/1000  1pc8.7/10kV, 9km below 300mm2;
26/35kV, 3km of cables below 300mm2;
Substation electrical equipment below 35kV
WDXZ-540/10830--220/380       1pc30--1.2/2.5/5/0.2/0.4     1pc67.5/27                 Section 8110/1000   1pc8.7/10kV, 12km cable below 300mm2;
26/35kV, 4km of cables below 300mm2;
Electrical AC withstand voltage test of 35kV substation
WDXZ-648/27025--/220/380      1pc25--1.2/2.5/5/15/0.2/0.4    1pc72/45                  Section  9270/400    1pc8.7/10kV, 6km of cables below 300mm2;
26/35kV, 2km of cables below 300mm2;
64/110kV, 1km of cables below 300mm2;
Substation electrical equipment below 110kV
WDXZ-1296/27050--380          1pc50--1.2/2.5/5/15/0.4     1pc648/135                 Section  2270/400     1pc64/110kV, 2km of cables below 300mm2;
127/220kV, 0.5km of cable below 630mm2;
Substation electrical equipment below 110kV
WDXZ-1760/44080--380       1pc80--1.2/2.5/5/15/25/0.4   1pc880/220                   Section  2440/400     1pc64/110kV, 1km cable below 300mm2;
127/220kV, 1km of cables below 630mm2;
Substation electrical equipment below 220kV





发货.jpg



联系我们.jpg 

Wechat:sallyliao ( 13657267902)

Email:info@wgdchipot.com

Whatsapp: +86 13657267902

Skype:  sallyliao2006